- Manufactured under high quality requirement of Japan which calls for continuously operating pilot gas burner with dedicated gas train
- On / Off, Two stage and Proportional control burners are available
- Fan motor can be bypassed easily without major changes in burner wiring / operation
- Can fire LPG and also LNG without any capacity derating
- Higher capacity burners come with UV scanner
Specification
| MODEL |
OUTPUT KCAL/HR |
OUTPUT KW |
CONTROL |
MOTOR WATT / PHASE |
| AG - 5S |
50000 |
59 |
ON - OFF |
40 / 1Ø |
| AG - 10S |
100000 |
118 |
ON - OFF |
150 / 1Ø |
| AG - 15S |
150000 |
176 |
ON - OFF |
250 / 1Ø |
| AG - 25S |
250000 |
294 |
ON - OFF |
400 / 3Ø |
| AG - 30S |
300000 |
353 |
ON - OFF |
400 / 3Ø |
| AG - 40S |
400000 |
471 |
ON - OFF |
750 / 3Ø |
| AG - 45S |
450000 |
529 |
ON - OFF |
750 / 3Ø |
| AG - 60S |
600000 |
706 |
ON - OFF |
1000 / 3Ø |
| AG - 5WS |
50000 |
59 |
TWO STAGE |
40 / 1Ø |
| AG - 10WS |
100000 |
118 |
TWO STAGE |
150 / 1Ø |
| AG - 15WS |
150000 |
176 |
TWO STAGE |
250 / 1Ø |
| AG - 25WS |
250000 |
294 |
TWO STAGE |
400 / 3Ø |
| AG - 30WS |
300000 |
353 |
TWO STAGE |
400 / 3Ø |
| AG - 40WS |
400000 |
471 |
TWO STAGE |
750 / 3Ø |
| AG - 45WS |
450000 |
529 |
TWO STAGE |
750 / 3Ø |
| AG - 60WS |
600000 |
706 |
TWO STAGE |
1000 / 3Ø |
| AG - 80WS |
800000 |
941 |
TWO STAGE |
1500 / 3Ø |
| AGP - 5S |
50000 |
59 |
PROPORTIONAL |
40 / 1Ø |
| AGP - 10S |
100000 |
118 |
PROPORTIONAL |
150 / 1Ø |
| AGP - 15S |
150000 |
176 |
PROPORTIONAL |
250 / 1Ø |
| AGP - 25S |
250000 |
294 |
PROPORTIONAL |
400 / 3Ø |
| AGP - 30S |
300000 |
353 |
PROPORTIONAL |
400 / 3Ø |
| AGP - 40S |
400000 |
471 |
PROPORTIONAL |
750 / 3Ø |
| AGP - 45S |
450000 |
529 |
PROPORTIONAL |
750 / 3Ø |
| AGP - 60S |
600000 |
706 |
PROPORTIONAL |
1000 / 3Ø |
| AGP - 80S |
800000 |
941 |
PROPORTIONAL |
1500 / 3Ø |
| AGP - 100S |
1000000 |
1176 |
PROPORTIONAL |
1500 / 3Ø |
| AGP - 150S |
1500000 |
1765 |
PROPORTIONAL |
2200 / 3Ø |
| AGP - 200S |
2000000 |
2353 |
PROPORTIONAL |
3700 / 3Ø |
| AGP - 250S |
2500000 |
2941 |
PROPORTIONAL |
5500 / 3Ø |
| AGP - 300S |
3000000 |
3529 |
PROPORTIONAL |
7500 / 3Ø |
Fuel Input Conditions:
- LPG: 280 mm WC (28 mBar)
- LNG: 200 mm WC (20 mBar) through filters
| Dimension |
 |
| Model |
A |
B |
C |
D |
E |
F |
φG |
H |
I |
J |
K |
| AG-5S |
250 |
270 |
270 |
275 |
115 |
100 |
101 |
200 |
180 |
- |
4-φ10 |
| AG-10S |
270 |
277 |
275 |
290 |
120 |
100 |
114 |
200 |
180 |
- |
4-φ10 |
| AG-15S |
362 |
293 |
360 |
365 |
135 |
100 |
140 |
270 |
240 |
- |
8-φ12 |
| AG-25S |
397 |
293 |
410 |
415 |
135 |
100 |
160 |
270 |
240 |
- |
8-φ12 |
| AG-30S |
425 |
305 |
440 |
470 |
135 |
120 |
180 |
270 |
240 |
- |
8-φ12 |
| AG-40S |
460 |
305 |
480 |
505 |
135 |
120 |
180 |
270 |
240 |
- |
8-φ12 |
| AG-45S |
460 |
305 |
480 |
505 |
135 |
120 |
180 |
270 |
240 |
- |
8-φ12 |
| AG-60S |
505 |
435 |
540 |
540 |
155 |
120 |
216 |
340 |
310 |
- |
8-φ12 |
| AGP-80S |
576 |
450 |
570 |
640 |
175 |
150 |
240 |
380 |
350 |
240 |
12-φ12 |
| AGP-100S |
576 |
460 |
570 |
650 |
182 |
150 |
260 |
400 |
364 |
240 |
12-φ12 |
| AGP-150S |
626 |
490 |
580 |
710 |
225 |
180 |
290 |
450 |
410 |
240 |
12-φ13 |
| AGP-200S |
676 |
510 |
600 |
760 |
245 |
180 |
330 |
490 |
450 |
260 |
12-φ13 |
| AGP-250S |
910 |
525 |
640 |
1020 |
260 |
200 |
360 |
520 |
480 |
280 |
12-φ13 |
| AGP-300S |
950 |
550 |
660 |
1050 |
290 |
200 |
410 |
580 |
544 |
300 |
12-φ13 |
NOTE : Dimensional values above are all standard specifications. If you need special specifications, please ask us for the drawing separately. Piping dimensions vary a